分类: 动力与电气工程 >> 工程热物理学 提交时间: 2018-01-24 合作期刊: 《热科学学报》
摘要: Effects of the inlet guide vanes on the static characteristics, aerodynamic noise and internal flow characteristics of a small axial flow fan are studied in this work. The inlet guide vanes with different outlet angle are designed, which are mounted on the casing and located at the upstream of the impeller of the prototype fan. Both steady and unsteady flow simulations are performed. The steady flow is simulated by the calculations of Navier-Stokes equations coupled with RNG k-epsilon turbulence model, while the unsteady flow is computed with large eddy simulation. According to the theoretical analysis, the inlet guide vanes with outlet angle of 60 degrees are regarded as the optimal inlet guide vanes. The static characteristic experiment is carried out in a standard test rig and the aerodynamic noise is tested in a semi-anechoic room. Then, performances of the fan with optimal inlet guide vanes are compared with those of the prototype fan. The results show that there is reasonable agreement between the simulation results and the experimental data. It is found that the static characteristics of small axial flow fan is improved obviously after installing the optimal inlet guide vanes. Meanwhile, the optimal inlet guide vanes have effect on reducing noise at the near field, but have little effect on the noise at the far field.
分类: 物理学 >> 普通物理:统计和量子力学,量子信息等 提交时间: 2017-11-02 合作期刊: 《热科学学报》
摘要: A rack cooling system based on a large scale flat plate pulsating heat pipe is proposed. The heat generated from IT equipment in a closed rack is transferred by the rear door pulsating heat pipe to the chilled air passage and is avoided to release into the room. The influence of the start-up performance of the heat pipe, the load of the rack and the load dissipation to the temperature and the velocity distribution in the rack are discussed. It is found that the temperature would be lower and the temperature distribution would be more uniform in the rack when the pulsating heat pipe is in operation. Also, the effect of rack electricity load on temperature distribution is analyzed. It is indicated that higher velocity of chilled air will improve heat transfer of the rack.
分类: 动力与电气工程 >> 工程热物理学 提交时间: 2017-06-26 合作期刊: 《热科学学报》
摘要: In this work, tip end-plate is used to improve the noise performance of small axial fans. Both numerical simulations and experimental methods were adopted to study the fluid flow and noise level of axial fans. Four modified models and the prototype are simulated. Influences of tip end-plate on static characteristics, internal flow field and noise of small axial fans are analyzed. The results show that on basis of the prototype, the model with the tip end-plate of 2 mm width and changed length achieved best noise performance. The overall sound pressure level of the model with the tip end-plate of 2 mm width and changed length is 2.4 dB less than that of the prototype at the monitoring point in specified far field. It is found that the mechanism of noise reduction is due to the decrease of vorticity variation on the surface of blades caused by the tip end-plate. Compared with the prototype, the static pressure of the model with the tip end-plate of 2 mm width and changed length at design flow rate decreases by 2 Pa and the efficiency decreases by 0.8%. It is concluded that the method of adding tip end-plate to impeller blades has a positive influence on reducing noise, but it may diminish the static characteristics of small axial fan to some extent.